SERIES 800

TOTALIZING COUNTER
STOPWATCH/TIMER
Models
Options
Features
Series 800
Specifications
Case size: "A"


MODEL TIME BASE DISPLAY PRICE
804 Totalizing Counter 9.9.9.9 $328.00
810 Crystal 9999 seconds $347.00
811 Crystal 999.9 seconds $347.00
812 Crystal 99.99 seconds $347.00
813 Crystal 9.999 seconds $347.00
814 Crystal 9.59.9 min/sec/.1 sec $347.00
815 Crystal 999.9 minutes $347.00
816 Crystal 99.99 minutes $347.00
817 Crystal 9.999 minutes $347.00
831 50/60 Hz 999.9 seconds $329.00
832 50/60 Hz 9.59.9 min/sec/.1 sec $329.00
834 50/60 Hz 999.9 minutes $329.00
840 50/60 Hz 9999 seconds $329.00
851 Crystal 999.9 milliseconds $347.00
852 Crystal 99.99 milliseconds $347.00
853 Crystal 9.999 milliseconds $347.00

Prices subject to change without notice.
Top of page

OPTIONSDESCRIPTIONPRICE
  • 01
Buffered, latchable, three state BCD outputs, with single line enable.
(4 digits)
(6 digits)
$40.00
$60.00
  • 02
Add two digits to left of display to make a six digit display $30.00
  • 03
Add two digits to left of display on either 814 or 832 to make a six digit unit with a display of 9.59.59.9 hr/min/sec/.1 sec $40.00
  • 05
5VDC input power $15.00
  • 06
Stored display. Stop command will update display and this reading will be displayed until next stop command. NA with 07 & 09 option $30.00
  • 07
Alternate action start/stop. NA with 09 option$30.00
  • 08
Input amplifier for sine wave/pulse input signals Threshold is adjustable from front panel. (804 only) $30.00
  • 09
Stop override start (like ERC/ITC) NA with 06 & 09 option. $15.00
  • 10
Remove front panel switches $15.00
  • 12
10-15VDC input power $20.00
  • 18
Reset switch only $15.00
  • 22
230VAC + 10%, 50-400 Hz, input power $15.00
  • 23
Green LED display $60.00
  • 24
10-30VDC input power $60.00
  • 25
Special legends and/or logo,(Special artwork to be supplied by customer). One time charge $100.00
    Plus per lens $ 15.00
    • 26
    No logo $15.00
    • 27
    Screw terminal I/O connector $80.00
    • 28
    Blank lens $15.00
    • 31
    "SECONDS" legend $15.00
    • 32
    "MIN/SECONDS" legend $15.00
    • 33
    "MINUTES" legend $15.00
    • 34
    "HR/MINUTES/SECONDS" legend $15.00
    • 35
    "MILLISECONDS" legend $15.00
    • 36
    "COUNTER" legend $15.00
    • 50
    Sunlight readable red LED$40.00
    Prices subject to change without notice.
    Top of page



    FEATURES

    • Direct replacement for ERC/ITC Series 2600 and Series 2300
    • Four or six big (.56") LED digits of display
    • TTL compatible BCD outputs (optional)
    • Front panel and remote control inputs for start, stop, and reset
    • Crystal or 50/60 Hz timebase
    • Power interrupt indication
    • CMOS circuitry for high noise immunity and low power consumption
    • Schmitt trigger input circuitry for all TTL count inputs
    • Stopwatch resolutions from 1 microsecond to 100 seconds
    • Optional battery backup

    SERIES 800
    Top of page

    SERIES 800
    Accurate timing of relay closures, switch closures, or TTL logic levels with resolutions down to one microsecond are easily accomplished using the remote inputs for start, stop, and reset. These remote inputs are standard on all Series 800 units as well as the front panel controls. An option for stored display enables the display to be held from one stop command to the next stop command which permits the reading of short time intervals without the annoyance of seeing the display change or having to wait until the end of the time cycle to see the reading. Optional latchable parallel BCD outputs with three state control extend capabilities to control functions when used with a comparator or interfacing with a printer or microprocessor system. When used as a totalizing counter the input count signal can be as low as 200 mV or up to 115 volts with option 08. Schmitt trigger inputs are used on all TTL count inputs to prevent false triggering and can be configured for counting form A contact closure simply by adding input filter capacitors.

    Top of page

    SPECIFICATIONS
    Accuracy:
    Display:
    Controls:
    Remote Inputs:
    Outputs:
    Count Inputs: (counter only)
    Power:
    Operating Temperature Range:
    I/O Method:
    Case Size:



    1 pwr interrupt/light test
    2 NC
    3 ext start (normally high, low enables)
    4 ext stop (normally high, low enables)
    5 ext reset (normally high, low enables)
    6 reset out
    7 115VA *
    8 NC
    9 115VAC *
    10 count out
    11 out of range
    12 one megahertz (crystal unit only)
    13 unreg 5V
    14 common
    15 5V

    1 high-non zero crossing (option -08)
    2 high-zero crossing (option -08)
    3 signal return (option -08)
    4 TTL signal input (option 08 use pin 1)
    5 N.C. contact closure input
    6. N.O.
    7 115Vac power *
    8 remote reset
    9 115VAC power *
    10 remote stop
    11 reset output
    12 remote start (one megahertz 874 only)
    13 unregulated
    14 common
    15 5V

    *Optional 220 VAC or VDC power input

    LSD ---------4 A 1 4---------
    1st digit 2 B 2 2 3rd digit
    BCD 8 C 3 8 BCD
    ---------1 D 4 1---------
    ---------4 E 5 4---------
    2nd digit 2 F 6 2 4th digit
    BCD 8 H 7 8 BCD
    ---------1 J 8 1---------
    ---------4 K 9 4---------
    5th digit 2 L 10 2 6th digit
    BCD 8 M 11 8 BCD
    ---------1 N 12 1---------
    (Normally high, low enables) latch P 13 three state control (normally high, low enables)
    common R 14 common
    5V S 15 5V

    Top of page

    CASE SIZE: "A"